Yaesu FTDX-5000
Lutz Kahlbau DH7LK dh7lk@yahoo.de
Original File for FTDX3000 by
Tim Gimmel KB4AMA
Verified
Version: 2.24
Date: 16. July 2019
New in V2.24
Power Meter values scale corrected
New in V2.23
Minor addition: at start up Roofing Filter is set to auto.
If Roofing Filter is not auto, narrow roofing settings could limit broader bandwith settings.
New in V2.21 and V2.22
Minor optimations
New in V2.20:
At startup the status will be saved in Memory 99 and
at shutdown the status will be restored from Memory 99.
At Startup the rig will be set for digi modes (USB
Packet, BW 1.2 kHz)
Changes to V2.00: S-Meter, PWR-Meter and Notch-Filter added
For Fldigi 3.23.08.16 or higher
RigCAT-FTDX5000
false
500
2
5
50
4800
2
5
false
false
true
INIT
63
MC099;AM;MD0C;NA00;SH012;GT01;NR00;BC00;BP00000;NB00;CO0000;RC;RF00;
CLOSE
9
MC099;MA;
PKT-USB
0C
PKT-LSB
08
PKT-FM
0A
RTTY-USB
09
RTTY-LSB
06
CW-USB
03
CW-LSB
07
USB
02
LSB
01
FM
04
FM-N
0B
AM
05
AM-N
0D
LSB
CW-LSB
PKT-LSB
RTTY-LSB
50/200 SSB
NA01;SH001
100/400 SSB
NA01;SH002
150/600 SSB
NA01;SH003
200/850 SSB
NA01;SH004
250/1.1 SSB
NA01;SH005
300/1.35 SSB
NA01;SH006
350/1.5 SSB
NA01;SH007
400/1.65 SSB
NA01;SH008
450/1.8 SSB
NA01;SH009
500/1.95 SSB
NA00;SH010
800/2.1 SSB
NA00;SH011
1.2/2.25 SSB
NA00;SH012
1.4/2.4 SSB
NA00;SH013
1.7/ no SSB
NA00;SH014
2.0/2.5 SSB
NA00;SH015
2.4/2.6 SSB
NA00;SH016
2.7 SSB
NA00;SH017
2.8 SSB
NA00;SH018
2.9 SSB
NA00;SH019
3.0 SSB
NA00;SH020
3.2 SSB
NA00;SH021
3.4 SSB
NA00;SH022
3.6 SSB
NA00;SH023
3.8 SSB
NA00;SH024
4.0 SSB
NA00;SH025
50/200 SSB
01
100/400 SSB
02
150/600 SSB
03
200/850 SSB
04
250/1.1 SSB
05
300/1.35 SSB
06
350/1.5 SSB
07
400/1.65 SSB
08
450/1.8 SSB
09
500/1.95 SSB
10
800/2.1 SSB
11
1.2/2.25 SSB
12
1.4/2.4 SSB
13
1.7/ no SSB
14
2.0/2.5 SSB
15
2.4/2.6 SSB
16
2.7 SSB
17
2.8 SSB
18
2.9 SSB
19
3.0 SSB
20
3.2 SSB
21
3.4 SSB
22
3.6 SSB
23
3.8 SSB
24
4.0 SSB
25
0,0; 256,100
SMETER
7
RM1
DECIMAL
3
;
GET_SMETER
4
RM1;
SMETER
0,0; 41,5; 52,10; 67,20; 83,30; 111,50; 135,75; 159,100; 193,150; 213,180; 223,200; 255,250
PWRMETER
7
RM5
DECIMAL
3
;
GET_PWRMETER
4
RM5;
PWRMETER
0,0; 255,200;
PWRLEVEL
6
PC
DECIMAL
3
;
GET_PWRLEVEL
3
PC;
PWRLEVEL
SET_PWRLEVEL
6
PC
DECIMAL
3
;
1,10; 300,3000;
SET_NOTCH_ON
8
BP00001;
SET_NOTCH_OFF
8
BP00000;
SET_NOTCH_VAL
8
BP01
DECIMAL
3
;
NOTCH_ON
8
BP00001;
GET_NOTCH_ON
5
BP00;
NOTCH_ON
NOTCH
8
BP01
DECIMAL
3
;
GET_NOTCH
5
BP01;
NOTCH
SETBW
11
STRING
10
;
BW
GETBW
6
SH0;
BW
BW
6
SH0
STRING
2
;
MODE
5
MD
STRING
2
;
FREQ
11
FA
DECIMAL
8
60000000
0030000
1
false
;
SETFREQ
11
FA
DECIMAL
8
60000000
0030000
1
false
;
?;
GETFREQ
3
FA;
FREQ
SETMODE
5
MD
STRING
2
;
MODE
GETMODE
4
MD0;
MODE
PTTON
4
TX1;
PTTOFF
4
TX0;